Just got new model Xhorse Dolphin XP005L Key Cutting Machine recently. Find bitting codes when all key lost is the one feature I was most pleased with. I can fill in a quick code to easily find out key type. Following I’m gonna show how to do. Taking this 1410 key number as an example. I was looking for this key many times, but they were not accurate. Let’s try on this machine. This key is a Hyundai Kefico, I will enter into B1410. All key lost >> Hyundai >> B1410 Dolphin XP005L is giving several key types for selection. It seems to be HYN15. HYN15 >> OK As you can see, Dolphin II shows me all key bitting codes here: 24233211 Compare to the original one. It’s same! It should be the correct one I selected. Once confirmed, I can also cut key here directly. This is how to use Xhorse Dolphin II to find bitting codes when all keys lost. I’ll try it to update more reviews... www.xhorse.co.uk
Posts
Showing posts from January, 2022
Dolphin XP-005 Probe & Cutter Abnormal Conductivity Self-Inspection
- Get link
- X
- Other Apps
How to do in case Xhorse Dolphin XP-005 occurs an “ERROR CODE:57, Probe short circuit, please check probe electrical conductivity”? After clearing probes and doing self-test in Electrical Conductivity Measurement, this problem may be solved. If unfortunately, all that do not work, you’ll have to detect probe & milling cutter abnormal conductivity by yourself. Method 1. Separating the rear cover, be careful of the wiring harness when operation. 2. Remove wire harness Phillips screws(pic3). Remove rubber pellets to take out screws inside. Remove the long strip with a HEX screwdriver.(pic4). 3. Rotate the lead screw with a flat-blade screwdriver. Align Z-axis as the cover in same horizontal line(pic5-6). Remove Z-axis housing after alignment, install the probe next to it(pic6). Remove screws in (pic7). Note: please be careful of a conductive wire inside probe(pic8). 4. Inspect whether the wires of probe & milling cutter are conductive or short. Please connect with main board for ...